Set Homepage | Favorite
Hot key words:Pure nickel wire   ┆    Constantan wire   ┆    Nickel chrome wire  ┆    Thermocouple wire
Product Detail

Product Detail

Product Details

E type compensation cable

E type compensation cable
Product Details

1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.


Thermocouple variety and index

Thermocouple Variety and Index

Variety

Type

Measurement Range(°C)

NiCr-NiSi

K

-200-1300

NiCr-CuNi

E

-200-900

Fe-CuNi

J

-40-750

Cu-CuNi

T

-200-350

NiCrSi-NiSi

N

-200-1300

NiCr-AuFe0.07

NiCr-AuFe0.07

-270-0


3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire
Dimensions / Tolerance mm ) : 4.0+/-0.25

Color code & initial calibration tolerances for thermocouple wire:

Thermocouple Type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

+/-
Conductor

Jacket

Temperature
Range

Standard
Limits

Special
Limits

Iron(+) vs.
Constantan(-)

J

White/Red

Brown

0°C to +285°C
285°C to +750°C

±2.2°C
± .75%

±1.1°C
± .4%

CHROMEL(+) vs.
ALUMEL(-)

K

Yellow/Red

Brown

-200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C

± 2%
±2.2°C
±2.2°C
± .75%

±1.1°C
± .4%

Copper(+) vs.
Constantan(-)

T

Blue/Red

Brown

-200°C to -65°C
-65°C to +130°C
130°C to +350°C

± 1.5%
±1°C
± .75%

± .8%
± .5°C
± .4%

CHROMEL(+) vs.
Constantan(-)

E

Purple/Red

Brown

-200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C+900°C

± 1%
±1.7°C
±1.7°C
± .5%

±1°C
±1°C
± .4%
± .4%


Color Code & Initial Calibration Tolerance for Extension Wire:

Extension type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

+/-
Conductor

Jacket

Temperature Range

Standard
Limits

Special
Limits

Iron (+) vs.

Constantan(-)

JX

White/Red

Black

0°C to +200°C

±2.2°C

±1.1°C

CHROMEL (+) vs.

ALUMEL (-)

KX

Yellow/Red

Yellow

0°C to +200°C

±2.2°C

±1.1°C

Copper(+) vs.

Constantan(-)

TX

Blue/Red

Blue

-60°C to +100°C

±1.1°C

± .5°C

CHROMEL(+) vs.

Constantan(-)

EX

Purple/Red

Purple

0°C to +200°C

±1.7°C

±1.1°C


PVC-PVC Physical Properties:

Characteristics

Insulation

Jacket

Abrasion Resistance

Good

Good

Cut Through Resistance

Good

Good

Moisture Resistance

Excellent

Excellent

Solder Iron Resistance

Poor

Poor

Service Temperature

105ºC continuous
150ºC single

105ºC continuous
150ºC single

Flame Test

Self-extinguishing

Self-extinguishing


Tel:0519-85500938             Phone:15261134748 Address: Gate 6, No. 5, Heng'an Road, Zhenglu Town, Tianning District, Changzhou City, Jiangsu, China
CHANGZHOU CHUANGXIN INSTRUMENT MATERIALS CO.,LTD.
ABOUTUS           PRODUCTS           NEWS           MESSAGE            CONTACT